Drinking water quality standards

Drinking water quality standards describes the quality parameters set for drinking water. Despite the truth that every human on this planet needs drinking water to survive and that water may contain many harmful constituents, there are no universally recognized and accepted international standards for drinking water.[1] Even where standards do exist, and are applied, the permitted concentration of individual constituents may vary by as much as ten times from one set of standards to another.

Many developed countries specify standards to be applied in their own country. In Europe, this includes the European Drinking Water Directive[2] and in the United States the United States Environmental Protection Agency (EPA) establishes standards as required by the Safe Drinking Water Act. For countries without a legislative or administrative framework for such standards, the World Health Organization publishes guidelines on the standards that should be achieved.[3] China adopted its own drinking water standard GB3838-2002 (Type II) enacted by Ministry of Environmental Protection in 2002.[4]

Where drinking water quality standards do exist, most are expressed as guidelines or targets rather than requirements, and very few water standards have any legal basis or, are subject to enforcement.[5] Two exceptions are the European Drinking Water Directive and the Safe Drinking Water Act in the United States, which require legal compliance with specific standards.

In Europe, this includes a requirement for member states to enact appropriate local legislation to mandate the directive in each country. Routine inspection and, where required, enforcement is enacted by means of penalties imposed by the European Commission on non-compliant nations.

Countries with guideline values as their standards include Canada, which has guideline values for a relatively small suite of parameters, New Zealand, where there is a legislative basis, but water providers have to make "best endeavours" to comply with the standards,[6] and Australia.

Range of standards

Although drinking water standards frequently are referred to as if they are simple lists of parametric values, standards documents also specify the sampling location, sampling methods, sampling frequency, analytical methods, and laboratory accreditation AQC. In addition, a number of standards documents also require calculation to determine whether a level exceeds the standard, such as taking an average. Some standards give complex, detailed requirements for the statistical treatment of results, temporal and seasonal variations, summation of related parameters, and mathematical treatment of apparently aberrant results.

Parametric values

(Parametric value also has a specific and different mathematical meaning)

A parametric value in this context is most commonly the concentration of a substance, e.g. 30 mg/l of Iron. It may also be a count such as 500 E. coli per litre or a statistical value such as the average concentration of copper is 2 mg/l. Many countries not only specify parametric values that may have health impacts but also specify parametric values for a range of constituents that by themselves are unlikely to have any impact on health. These include colour, turbidity, pH, and the organoleptic (aesthetic) parameters (taste and odour).

It is possible and technically acceptable to refer to the same parameter in different ways that may appear to suggest a variation in the standard required. For example, nitrite may be measured as nitrite ion or expressed as N. A standard of "Nitrite as N" set at 1.4 mg/l equals a nitrite ion concentration of 4.6 mg/l. This is an apparent difference of nearly threefold.

Standards by country

Australia

Drinking water quality standards in Australia have been developed by the Australian Government National Health and Medical Research Council (NHMRC) in the form of the Australian Drinking Water Guidelines.[7] These guidelines provide contaminant limits (pathogen, aesthetic, organic, inorganic, and radiological) as well as guidance on applying limits for the management of drinking water in Australian drinking water treatment and distribution.

European Union

The following parametric standards are included in the Drinking Water Directive and are expected to be enforced by appropriate legislation in every country in the European Union. Simple parametric values are reproduced here, but in many cases the original directive also provides caveats and notes about many of the values given.[8]

United States

In the United States, the federal legislation controlling drinking water quality is the Safe Drinking Water Act (SDWA) which is implemented by the U.S. Environmental Protection Agency (EPA), mainly through state or territorial health agencies.[9][10]

EPA has set standards for over 90 contaminants organized into six groups: microorganisms, disinfectants, disinfection byproducts, inorganic chemicals, organic chemicals and radionuclides.[11] States and territories must implement rules that are at least as stringent as EPA's to retain primary enforcement authority (primacy) over drinking water. Many states also apply their own state-specific standards, which may be more rigorous or include additional parameters.[12] Many countries look to the standards set by the EPA in the United States for appropriate scientific and public health guidance and may reference or adopt US standards.

World Health Organization Guidelines

The World Health Organization (WHO) Guideline for Drinking-water Quality (GDWQ) include the following recommended limits on naturally occurring constituents that may have direct adverse health impact:

  • Arsenic 10μg/l
  • Barium 10μg/l
  • Boron 2400μg/l
  • Chromium 50μg/l
  • Fluoride 1500μg/l
  • Selenium 40μg/l
  • Uranium 30μg/l

Organic species:

  • Benzene 10μg/l
  • Carbon tetrachloride 4μg/l
  • 1,2-Dichlorobenzene 1000μg/l
  • 1,4-Dichlorobenzene 300μg/l
  • 1,2-Dichloroethane 30μg/l
  • 1,2-Dichloroethene 50μg/l
  • Dichloromethane 20μg/l
  • Di(2-ethylhexyl)phthalate 8 μg/l
  • 1,4-Dioxane 50μg/l
  • Edetic acid 600μg/l
  • Ethylbenzene 300 μg/l
  • Hexachlorobutadiene 0.6 μg/l
  • Nitrilotriacetic acid 200μg/l
  • Pentachlorophenol 9μg/l
  • Styrene 20μg/l
  • Tetrachloroethene 40μg/l
  • Toluene 700μg/l
  • Trichloroethene 20μg/l
  • Xylene 500μg/l

Comparison of parametric values

The following table provides a comparison of a selection of parameters for concentrations listed by WHO, the European Union, EPA, and Ministry of Environmental Protection of China.

" indicates that no standard has been identified by editors of this article and ns indicates that no standard exists. μg/l -> Micro grams per litre or 0.001 ppm, mg/L -> 1 ppm or 1000 μg/l
* Action level; not a concentration standard. A public water system exceeding the action level must implement "treatment techniques" which are enforceable procedures.[13]
** TT (treatment technique). The public water system must certify that the combination of dose and monomer level does not exceed: Acrylamide = 0.05% dosed at 1 mg/l (or equivalent); Epichlorohydrin = 0.01% dosed at 20 mg/l (or equivalent).[11]

Parameter Table World Health Organization European Union United States China Canada [14] India (BIS)[15]
1,2-dichloroethane " 3.0 μg/l 5 μg/l " "
Acrylamide " 0.10 μg/l TT** " "
Aluminium Al 0,2 mg/l no limit listed 0.03 mg/l
Antimony Sb ns 5.0 μg/l 6.0 μg/l " 6.00 μg/l
Arsenic As 10μg/l 10 μg/l 10μg/l 50μg/l 10.0 μg/l 0.05 mg/l
Barium Ba 700μg/l ns 2 mg/L " 1.00 mg/L
Benzene 10μg/l 1.0 μg/l 5 μg/l " "
Benzo(a)pyrene " 0.010 μg/l 0.2 μg/l 0.0028 μg/l "
Beryllium Be "
Boron B 2.4 mg/l 1.0 mg/L " " 5.00 mg/L 1.0 mg/l
Bromate " 10 μg/l 10 μg/l " "
Cadmium Cd 3 μg/l 5 μg/l 5 μg/l 5 μg/l 5.00 μg/l 0.01 mg/l
Calcium Ca 200 mg/L 75 mg/l
Chromium Cr 50μg/l 50 μg/l 0.1 mg/L 50 μg/l (Cr6) 0.050 mg/L 0.05 mg/l
Cobalt Co "
Copper Cu " 2.0 mg/l 1.3 mg/l* 1 mg/l 1.00 mg/L 0.05 mg/l
Cyanide " 50 μg/l 0.2 mg/L 50 μg/l " 0.05 mg/l
Epichlorohydrin " 0.10 μg/l TT** " "
Fluoride 1.5 mg/l 1.5 mg/l 4 mg/l 1 mg/l " 1.0 mg/l
Gold Au no limit listed
hardness CaCO3 0–75 mg/L = soft 300 mg/l
Iron Fe 0,2 mg/l 0.300 mg/L 0.3 mg/l
Lanthanum La no limit listed
Lead Pb " 10 μg/l 15 μg/l* 10 μg/l 10.0 μg/l 0.05 mg/l
Magnesium Mg 50.0 mg/L 30 mg/l
Manganese Mn 0, 05 mg/l 0.050 mg/L 0.1 mg/l
Mercury Hg 6 μg/l 1 μg/l 2 μg/l 0.05 μg/l 1.00 μg/l 0.001 mg/l
Molybdenum Mo no limit listed
Nickel Ni " 20 μg/l " " no limit listed
Nitrate 50 mg/l 50 mg/l 10 mg/L (as N) 10 mg/L (as N) " 45 mg/l
Nitrite 3 mg/l 0.50 mg/l 1 mg/L (as N) " "
Pesticides — Total " 0.50 μg/l " " " Absent
Pesticides (individual) " 0.10 μg/ l " " "
pH 6.5 to 8.5 6.5 to 8.5
Phosphorus P no limit listed
Polycyclic aromatic hydrocarbons l " 0.10 μg/ " " "
Potassium K no limit listed
Scandium Sc no limit listed
Selenium Se 40 μg/l 10 μg/l 50 μg/l 10 μg/l 10.0 μg/l 0.01 mg/l
Silicon Si no limit listed
Silver Ag 0.050 mg/L
Sodium Na 200 mg/L
Strontium Sr no limit listed
Tetrachloroethene and Trichloroethene 40μg/l 10 μg/l " " "
Tin Sn no limit listed
Titanium Ti no limit listed
Tungsten W no limit listed
Uranium U 0.10 mg/L
Vanadium V no limit listed
Zinc Zn 5.00 mg/L 5.0 mg/l
vinyl chloride 0,50 μg/l
chlorides 250 mg/l 250 mg/l
electrical conductivity 2500 μS cm-1 at 20 °C
Total Dissolved Solids 500 mg/l
Sulphate 200 mg/l

See also

References

  1. Shmueli, Deborah F. (May 1999). "Water quality in international river basins". Political Geography. 18 (4): 437–476. doi:10.1016/S0962-6298(98)00106-1. Pdf.
  2. European Drinking Water Directive
  3. Guidelines for Drinking-water Quality, Fourth Edition; World Health Organization; 2011
  4. "Environmental quality standards for surface water".
  5. What is the purpose of drinking water quality guidelines/regulations?. Canada: Safe Drinking Water Foundation. Pdf. Archived 2011-10-06 at the Wayback Machine
  6. "Health (Drinking Water) Amendment Act 2007". drinkingwater.co.nz. Drinking water for New Zealand. 2007. Archived from the original on 2012-07-24. Retrieved 2011-08-09.
  7. Australian Drinking Water Guidelines (2011)
  8. "Council Directive 98/83/EC of 3 November 1998 on the quality of water intended for human consumption, ANNEX I: PARAMETERS AND PARAMETRIC VALUES, PART B: Chemical parameters". EUR-Lex. Retrieved 30 December 2019.
  9. "Primacy Enforcement Responsibility for Public Water Systems". Drinking Water Requirements for States and Public Water Systems. Washington, D.C.: United States Environmental Protection Agency (EPA). 2016-11-02.
  10. Joseph Cotruvo, Victor Kimm, Arden Calvert. "Drinking Water: A Half Century of Progress." EPA Alumni Association. March 1, 2016.
  11. "National Primary Drinking Water Regulations". Ground Water and Drinking Water. EPA. 2019-09-17.
  12. Understanding the Safe Drinking Water Act (Report). EPA. June 2004. EPA 816-F-04-030.
  13. "How EPA Regulates Drinking Water Contaminants". EPA. 2019-06-06.
  14. As per Canadian or B.C. Health Act Safe Drinking Water Regulation BC Reg 230/92, & 390 Sch 120, 2001. Task Force of Canadian Council of Resource & Envir. Ministers Guidelines for Canadian Drinking Water Quality, 1996. Amend. Health Canada (2006).
  15. "Indian Standard Drinking Water Specification" (PDF). Central Ground Water Board.

Further reading

This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.