Recombinase polymerase amplification

Recombinase polymerase amplification (RPA) is a single tube, isothermal alternative to the polymerase chain reaction (PCR).[1] By adding a reverse transcriptase enzyme to an RPA reaction it can detect RNA as well as DNA, without the need for a separate step to produce cDNA,.[2][3][4] Because it is isothermal, RPA can use much simpler equipment than PCR, which requires a thermal cycler. Operating best at temperatures of 37–42 °C and still working, albeit more slowly, at room temperature means RPA reactions can in theory be run quickly simply by holding a tube. This makes RPA an excellent candidate for developing low-cost, rapid, point-of-care molecular tests. An international quality assessment of molecular detection of Rift Valley fever virus performed as well as the best RT-PCR tests, detecting less concentrated samples missed by some PCR tests and an RT-LAMP test.[5] RPA was developed and launched by TwistDx Ltd. (formerly known as ASM Scientific Ltd), a biotechnology company based in Cambridge, UK.

Technique

The RPA process employs three core enzymes – a recombinase, a single-stranded DNA-binding protein (SSB) and strand-displacing polymerase. Recombinases are capable of pairing oligonucleotide primers with homologous sequence in duplex DNA.[1] SSB bind to displaced strands of DNA and prevent the primers from being displaced. Finally, the strand displacing polymerase begins DNA synthesis where the primer has bound to the target DNA. By using two opposing primers, much like PCR, if the target sequence is indeed present, an exponential DNA amplification reaction is initiated. No other sample manipulation such as thermal or chemical melting is required to initiate amplification. At optimal temperatures (37–42 °C), the reaction progresses rapidly and results in specific DNA amplification from just a few target copies to detectable levels, typically within 10 minutes, for rapid detection of viral genomic DNA or RNA,[2][3][4][6][7][8] pathogenic bacterial genomic DNA,[9][10] as well as short length aptamer DNA.[11]

The three core RPA enzymes can be supplemented by further enzymes to provide extra functionality. Addition of exonuclease III allows the use of an exo probe for real-time, fluorescence detection akin to real-time PCR.[1] Addition of endonuclease IV means that a nfo probe can be used for lateral flow strip detection of successful amplification,.[1][6][12] If a reverse transcriptase that works at 37–42 °C is added then RNA can be reverse transcribed and the cDNA produced amplified all in one step. Currently only the TwistAmp exo version of RPA is available with the reverse transcriptase included, although users can simply supplement other TwistAmp reactions with a reverse transcriptase to produce the same effect. As with PCR, all forms of RPA reactions can be multiplexed by the addition of further primer/probe pairs, allowing the detection of multiple analytes or an internal control in the same tube.

Relationship to other amplification techniques

RPA is one of several isothermal nucleic acid amplification techniques to be developed as a molecular diagnostic technique, frequently with the objective of simplifying the laboratory instrumentation required relative to PCR. A partial list of other isothermal amplification techniques include LAMP, NASBA, helicase-dependent amplification (HDA), and nicking enzyme amplification reaction (NEAR). The techniques differ in the specifics of primer design and reaction mechanism, and in some cases (like RPA) make use of cocktails of two or more enzymes. Like RPA, many of these techniques offer rapid amplification times with the potential for simplified instrumentation, and reported resistance to substances in unpurified samples that are known to inhibit PCR. With respect to amplification time, modern thermocyclers with rapid temperature ramps can reduce PCR amplification times to less than 30 minutes, particularly for short amplicons using dual-temperature cycling rather than the conventional three-temperature protocols.[13] In addition, the demands of sample prep (including lysis and extraction of DNA or RNA, if necessary) should be considered as part of the overall time and complexity inherent to the technique. These requirements vary according to the technique as well as to the specific target and sample type.

Compared to PCR, the guidelines for primer and probe design for RPA are less established, and may take a certain degree of trial and error, although recent results indicate that standard PCR primers can work as well.[14] The general principle of a discrete amplicon bounded by a forward and reverse primer with an (optional) internal fluorogenic probe is similar to PCR. PCR primers may be used directly in RPA, but their short length means that recombination rates are low and RPA will not be especially sensitive or fast. Typically 30–38 base primers are needed for efficient recombinase filament formation and RPA performance. This is in contrast to some other techniques such as LAMP which use a larger number of primers subject to additional design constraints. Although the original 2006 report of RPA describes a functional set of reaction components, the current (proprietary) formulation of the TwistAmp kit is "substantially different" [15] and is available only from the TwistDx supplier. This is in comparison to reaction mixtures for PCR which are available from many suppliers, or LAMP or NASBA for which the composition of the reaction mixture is freely published, allowing researchers to create their own customized "kits" from inexpensive ingredients.

Published scientific literature generally lacks detailed comparison of the performance of isothermal amplification techniques such as RPA, HDA, and LAMP relative to each other, often rather comparing a single isothermal technique to a "gold standard" PCR assay. This makes it difficult to judge the merits of these techniques independently from the claims of the manufacturers, inventors, or proponents. Furthermore, performance characteristics of any amplification technique are difficult to decouple from primer design: a "good" primer set for one target for RPA may give faster amplification or more sensitive detection than a "poor" LAMP primer set for the same target, but the converse may be true for different primer sets for a different target. An exception is a recent study comparing RT-qPCR, RT-LAMP, and RPA for detection of Schmallenberg virus and bovine viral diarrhea virus,[16] which effectively makes the point that each amplification technique has strengths and weaknesses, which may vary by the target, and that the properties of the available amplification techniques need to be evaluated in combination with the requirements for each application. As with PCR and any other amplification technique, there is obviously a publication bias, with poorly performing primer sets rarely deemed worthy of reporting.

References

  1. Piepenburg, Olaf; Williams, Colin H.; Stemple, Derek L.; Armes, Niall A. (2006). "DNA Detection Using Recombination Proteins". PLOS Biology. 4 (7): e204. doi:10.1371/journal.pbio.0040204. PMC 1475771. PMID 16756388.
  2. Euler, Milena; Wang, Yongjie; Nentwich, Oliver; Piepenburg, Olaf; Hufert, Frank T.; Weidmann, Manfred (2012). "Recombinase polymerase amplification assay for rapid detection of Rift Valley fever virus". Journal of Clinical Virology. 54 (4): 308–12. doi:10.1016/j.jcv.2012.05.006. PMID 22683006.
  3. Amer, H.M.; Abd El Wahed, A.; Shalaby, M.A.; Almajhdi, F.N.; Hufert, F.T.; Weidmann, M. (2013). "A new approach for diagnosis of bovine coronavirus using a reverse transcription recombinase polymerase amplification assay". Journal of Virological Methods. 193 (2): 337–40. doi:10.1016/j.jviromet.2013.06.027. PMC 7113639. PMID 23811231.
  4. Abd El Wahed, Ahmed; El-Deeb, Ayman; El-Tholoth, Mohamed; Abd El Kader, Hanaa; Ahmed, Abeer; Hassan, Sayed; Hoffmann, Bernd; Haas, Bernd; Shalaby, Mohamed A.; Hufert, Frank T.; Weidmann, Manfred (2013). Meng, Xiang-Jin (ed.). "A Portable Reverse Transcription Recombinase Polymerase Amplification Assay for Rapid Detection of Foot-and-Mouth Disease Virus". PLOS ONE. 8 (8): e71642. Bibcode:2013PLoSO...871642A. doi:10.1371/journal.pone.0071642. PMC 3748043. PMID 23977101.
  5. Escadafal, Camille; Paweska, Janusz T.; Grobbelaar, Antoinette; Le Roux, Chantel; Bouloy, Michèle; Patel, Pranav; Teichmann, Anette; Donoso-Mantke, Oliver; Niedrig, Matthias (2013). De Silva, Aravinda M (ed.). "International External Quality Assessment of Molecular Detection of Rift Valley Fever Virus". PLOS Neglected Tropical Diseases. 7 (5): e2244. doi:10.1371/journal.pntd.0002244. PMC 3662703. PMID 23717706.
  6. Boyle, D. S.; Lehman, D. A.; Lillis, L.; Peterson, D.; Singhal, M.; Armes, N.; Parker, M.; Piepenburg, O.; Overbaugh, J. (2013). "Rapid Detection of HIV-1 Proviral DNA for Early Infant Diagnosis Using Recombinase Polymerase Amplification". mBio. 4 (2): e00135–13. doi:10.1128/mBio.00135-13. PMC 3622927. PMID 23549916.
  7. Euler, M.; Wang, Y.; Otto, P.; Tomaso, H.; Escudero, R.; Anda, P.; Hufert, F. T.; Weidmann, M. (2012). "Recombinase Polymerase Amplification Assay for Rapid Detection of Francisella tularensis". Journal of Clinical Microbiology. 50 (7): 2234–8. doi:10.1128/JCM.06504-11. PMC 3405570. PMID 22518861.
  8. Euler, M.; Wang, Y.; Heidenreich, D.; Patel, P.; Strohmeier, O.; Hakenberg, S.; Niedrig, M.; Hufert, F. T.; Weidmann, M. (2013). "Development of a Panel of Recombinase Polymerase Amplification Assays for Detection of Biothreat Agents". Journal of Clinical Microbiology. 51 (4): 1110–7. doi:10.1128/JCM.02704-12. PMC 3666764. PMID 23345286.
  9. Sebastian K, Valentina R, Frank FB, Markus von NR (2014). "Multiplex isothermal solid-phase recombinase polymerase amplification for the specific and fast DNA-based detection of three bacterial pathogens". Microchimica Acta. 181 (13–14): 1715–1723. doi:10.1007/s00604-014-1198-5. PMC 4167443. PMID 25253912.
  10. Santiago-Felipe S, Tortajada-Genaro LA, Morais S, Puchades R, Maquieira Á (2015). "Isothermal DNA amplification strategies for duplex microorganism detection". Food Chem. 174: 509–515. doi:10.1016/j.foodchem.2014.11.080. hdl:10251/66087. PMID 25529713.
  11. Loo JF, Lau PM, Ho HP, Kong SK (2013). "An aptamer-based bio-barcode assay with isothermal recombinase polymerase amplification for cytochrome-c detection and anti-cancer drug screening". Talanta. 115: 159–165. doi:10.1016/j.talanta.2013.04.051. PMID 24054573.
  12. Rohrman, Brittany A.; Richards-Kortum, Rebecca R. (2012). "A paper and plastic device for performing recombinase polymerase amplification of HIV DNA". Lab on a Chip. 12 (17): 3082–8. doi:10.1039/c2lc40423k. PMC 3569001. PMID 22733333.
  13. "Rapid PCR". Dna.utah.edu. Retrieved 2014-06-21.
  14. "PCR primers work using standard RPA reagents". TwistDx. Retrieved 2015-10-19.
  15. "Publications". TwistDx. Retrieved 2014-06-21.
  16. Aebischer, Andrea (2014). "Rapid Genome Detection of Schmallenberg Virus and Bovine Viral Diarrhea Virus by Use of Isothermal Amplification Methods and High-Speed Real-Time Reverse Transcriptase PCR". Journal of Clinical Microbiology. 52 (6): 1883–92. doi:10.1128/JCM.00167-14. PMC 4042763. PMID 24648561.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.