Subscapularis muscle
The subscapularis is a large triangular muscle which fills the subscapular fossa and inserts into the lesser tubercle of the humerus and the front of the capsule of the shoulder-joint.
Subscapularis muscle | |
---|---|
Subscapularis muscle (in red). Ribs are shown as semi-transparent. | |
The subscapularis is difficult to see from the front (labeled middle right) | |
Details | |
Origin | Subscapular fossa |
Insertion | Lesser tubercle of humerus |
Artery | subscapular artery |
Nerve | Upper subscapular nerve, lower subscapular nerve (C5, C6) |
Actions | Internally rotates and adducts humerus; stabilizes shoulder |
Identifiers | |
Latin | Musculus subscapularis |
TA98 | A04.6.02.012 |
TA2 | 2460 |
FMA | 13413 |
Anatomical terms of muscle |
Structure
It arises from its medial two-thirds and from the lower two-thirds of the groove on the axillary border (subscapular fossa) of the scapula.
Some fibers arise from tendinous laminae, which intersect the muscle and are attached to ridges on the bone; others from an aponeurosis, which separates the muscle from the teres major and the long head of the triceps brachii.
The fibers pass laterally and coalesce into a tendon that is inserted into the lesser tubercle of the humerus and the anterior part of the shoulder-joint capsule. Tendinous fibers extend to the greater tubercle with insertions into the bicipital groove.
Relations
The tendon of the muscle is separated from the neck of the scapula by a large bursa, which communicates with the cavity of the shoulder-joint through an aperture in the capsule. The subscapularis is separated from the serratus anterior by the subscapularis (supraserratus) bursa.[1]
Nerve supply
The subscapularis is supplied by the upper and lower subscapular nerves, branches of the posterior cord of the brachial plexus. (C5-C6)
Function
The subscapularis rotates the head of the humerus medially (internal rotation) and adducts it; when the arm is raised, it draws the humerus forward and downward. It is a powerful defense to the front of the shoulder-joint, preventing displacement of the head of the humerus.
Clinical significance
Examination
The Gerber Lift-off test is the established clinical test for examination of the subscapularis.[2] The bear hug test (internal rotation while palm is held on opposite shoulder and elbow is held in a position of maximal anterior translation) for subscapularis muscle tears has high sensitivity. Positive bear-hug and belly press tests indicate significant tearing of subscapularis.[3]
Imaging
There is no singularly imaging device or technique for a satisfying and complete subscapularis examination, but rather the combination of the sagittal oblique MRI / short-axis US and axial MRI / long-axis US planes seems to generate useful results. Additionally, lesser tuberosity bony changes have been associated with subscapularis tendon tears. Findings with cysts seem to be more specific and combined findings with cortical irregularities more sensitive.[4]
Another fact typically for the subscapularis muscle is the fatty infiltration of the superior portions, while sparing the inferior portions.
Since the long biceps tendon absents itself from the shoulder joint through the rotator cuff interval, it is easily possible to distinguish between the supraspinatus and the subscapularis tendon. Those two tendons build the interval sling.
Ultrasonography
Mack et al. developed an ultrasonographic procedure with which it is possible to explore almost the complete rotator cuff within six steps. It unveils clearly the whole area from the subedge of the subscapularis tendon until the intersection between the infraspinatus tendon and musculus teres minor. One of six steps does focus on the subscapularis tendon. In the first instance the examinator guides the applicator to the proximal humerus as perpendicularly as possible to the sulcus intertubercularis. Gliding now medially shows the insertion of the subscapularis tendon.[5]
Longitudinal plane of the musculus subscapularis and its tendon
The subscapularis tendon lies approximately 3 to 5 cm under the surface. Quite deep for ultrasonography, and therefore displaying through a highly penetrative 5 MHz linear applicator is worth a try. And it really turned out to ease a detailed examination of the muscle which just abuts to the scapula. However, the tendon of primary interest does not get mapped as closely as desired. As anatomical analysis showed, it is only by external rotation possible to see the ventral part of the joint socket and its labrum. While at the neutral position the tuberculum minus occludes the view. Summing up it is through an external arm rotation and a medially applied 5 MHz sector sonic head possible to display the ventral part of the joint socket and its labrum with notedly lower echogenicity.[6]
The following sectional planes are defined for the sonographic examination of the different shoulder joint structures:[7]
Ventral transversal | Ventral sagittal medial | Ventral sagittal lateral | Lateral coronal | Lateral transversal/sagittal: | Dorsal transversal | Dorsal sagittal |
---|---|---|---|---|---|---|
subscapularis muscle (longitudinal) | subscapularis muscle (transversal) | Intertub. sulcus with long head of biceps brachii (longitudinal) | supraspinatus muscle (longitudinal) | supraspinatus muscle (transversal) | infraspinatus muscle (longitudinal) | supraspinatus muscle (transversal) |
Intertubercular sulcus with long head of biceps brachii (transversal) | Hill-Sachs-Lesio |
Tissue harmonic imaging
Primarily in abdominal imaging, tissue harmonic imaging (THI) gets more and more valued and used additionally to conventional ultrasonography.
THI involves the use of harmonic frequencies that originate within the tissue as a result of nonlinear wave front propagation and are not present in the incident beam. These harmonic signals may arise differently at anatomic sites with similar impedances and thus lead to higher contrast resolution.” Along with higher contrast resolution it has an elevated signal-to-noise ratio and significantly reduced inter- and intraobserver variability compared with conventional US. Additionally it is possible to nearly eliminate ordinary US artifacts, i.e. side-lobe, near-field artifacts, reverberation artifacts. As aforementioned THI has already led to enhanced abdominal, breast, vascular and cardiac sonography.
For musculo-skeletal aspects THI has not been used that much, although this method features some useful potential. For example, for the still tricky discrimination between the presence of a hypoechoic defect and/or loss of the outer tendon convexity/non-visualization of the tendon, that is between partial- and full-thickness rotator cuff tears.
In comparison to a checking MR Arthrography Strobel K. et al. has arrived at the conclusion that through THI it is possible to achieve a generally improved visibility of joint and tendon surfaces, especially superior for subscapularis tendon abnormalities.[8]
Additional images
Wikimedia Commons has media related to Subscapularis muscles. |
- Subscapularis muscle (shown in red). Animation.
- Same as the left, but the bones around the muscle are shown as semi-transparent.
- Transverse section of thorax featuring subscapularis muscle
- Diagram of the human shoulder joint
References
This article incorporates text in the public domain from page 440 of the 20th edition of Gray's Anatomy (1918)
- Milano, Giuseppe and Grasso, Andrea, Shoulder Arthroscopy: Principles and Practice, Springer Science & Business Media, Dec 16, 2013. ISBN 9781447154273. Accessed 2016-11-07.
- Simons, Stephen; Dixon, J Bryan (3 April 2017). "Physical examination of the shoulder". UpToDate. Retrieved 19 April 2017.
- Barth, Johannes R.H.; Burkhart, Stephen S.; De Beer, Joe F. (October 2006). "The Bear-Hug Test: A New and Sensitive Test for Diagnosing a Subscapularis Tear". Arthroscopy: The Journal of Arthroscopic and Related Surgery. 22 (10): 1076–1084. doi:10.1016/j.arthro.2006.05.005.
- Morag, Yoav; Jamadar, David A.; Miller, Bruce; Dong, Qian; Jacobson, Jon A. (2009). "The subscapularis: Anatomy, injury, and imaging". Skeletal Radiology. 40 (3): 255–69. doi:10.1007/s00256-009-0845-0. PMID 20033149.
- Mack, L A; Matsen, F A; Kilcoyne, R F; Davies, P K; Sickler, M E (1985). "US evaluation of the rotator cuff". Radiology. 157 (1): 205–9. doi:10.1148/radiology.157.1.3898216. PMID 3898216.
- Katthagen BD. et al.. Schultersonographie. Stuttgart. ISBN 3-13-719401-6
- Thelen M. et al.. Radiologische Diagnostik der Verletzungen von Knochen und Gelenken. Stuttgart [etc.]. Georg Thieme. 1993. ISBN 3-13-778701-7
- Strobel, Klaus; Zanetti, Marco; Nagy, Ladislav; Hodler, Juerg (2004). "Suspected Rotator Cuff Lesions: Tissue Harmonic Imaging versus Conventional US of the Shoulder1". Radiology. 230 (1): 243–9. doi:10.1148/radiol.2301021517. PMID 14631052.